The drive letter will increment to W:, X:, and Y: with when more USB storage devices are. Order by Part Number or Request a Quote. crio-9023 前面板 1 3 6 7 4 2 8 9 5 1. You can. It includes a Kintex-7 70T FPGA with LabVIEW FPGA Module. . LEDs 6. 0. rj-45 以太网端口2 곧 연락드리겠습니다! NATIONAL INSTRUMENTS CORP. Real-Timeコントローラ: cRIO-9022、cRIO-9023、cRIO-9024、およびcRIO-9025; CompactRIO再構成可能シャーシ: cRIO-9111、cRIO-9112、cRIO-9113、cRIO-9114、cRIO-9116、およびcRIO-9118;. FTP the ni-rt. I have set-up the IP address for the cRIO which is 10. Perspectives showcases how NI sees what’s next in the world of test and technology. 最近、Windowsベースのアプリケーションをヘッドレスのスタンドアロンアプリケーションに置き換えるためにcRIO-9057を購入しました。イーサネットポートの数が限られているため、cRIOをプログラミングするためにUSBインタフェースを使用していますが、ホストコンピュータのMeasurement & Automation. 11-28-2011 10:26 AM. cRIO-9023 cRIO-9024. How can I fix this? My cRIO expansion. 2. I'm using a cRIO-9024, but I can't find the relevant specs on sampling at 1Mhz for it. Note: The USB configuration cable is included. Hold the RESET button again until the STATUS LED turns solid orange or yellow. NI-RIO驱动程序. Board Model Name Board Part Number Range . You can FTP to the drive as well by specifying the drive letter. Note The NI-XNET software supports only National Instruments Automotive Ethernet, CAN, FlexRay, and LIN hardware products. Dear NI experts, I need to study the affect on temperature measurements of pt100, as i increase current passing through it. CompactRIO or CompactDAQ chassis with finned bottom: Below compliance. 800 MHz CPU, 512 MB DRAM, 4 GB Storage CompactRIO Controller (Legacy)Hi All, I'm trying to use the 9223 module to sample at 1Mhz using User-Controlled IO Sampling. SNTPサーバと同期するようにコントローラーを構成するには、次の手順を行います。. To configure the controller to synchronize to an SNTP server, go through the following steps: 1. The NI cRIO-9024 rugged, reliable controller is designed for low-power consumption with dual 9 to 35 VDC supply inputs that deliver isolated power to the CompactRIO chassis/modules and a -20 to 55 °C operating temperature range. 한국내쇼날인스트루먼트㈜ | 주소: 서울특별시 영등포구 여의대로 108, 36층 (여의도동, 파크원 타워1) | 대표자: 수리후앗, 페드로와이안드라데 | 사업자 등록번호: 214-81-91583 | 대표전화: 02-3451-3400. 800 MHz CPU,512 MB DRAM,4 GB存储容量CompactRIO控制器(旧版) —cRIO‑9024是一款嵌入式实时控制器,是高级控制和监控应用的理想选择。. Jared S. Active Participant 01-12-2011. This rugged, fanless controller features a variety of connectivity ports, including two Ethernet, one USB, and one serial. Version 1. Read this to learn more. Trusted Enthusiast. LabVIEW 2011 SP1 FPGA Module or later. NI-Serial 19. Template page for every B2B supported Model Page. 0. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. Microsoft Visual C/C++. Higher density modules conserve chassis space, which leaves room for other measurement types. 800 MHz CPU, 512 MB DRAM, 4 GB Storage CompactRIO Controller (Legacy)800 MHz CPU, 512 MB DRAM, 4 GB Storage CompactRIO Controller (Legacy)800 MHz CPU, 512 MB DRAM, 4 GB Storage CompactRIO Controller (Legacy)CompactRIO 902xシリーズターゲット(cRIO-9022、cRIO-9023、cRIO-9024、cRIO-9025) 影響を受けるLabVIEW Real-Timeアプリケーションを識別する方法 すべての開発者がアプリケーションを評価し、この問題の影響を受けているかどうかを判断することをナ. The main parts of the cRIO system are: a real -time computer, a Field -Programmable Gate Array (FPGA) module, and a slots' bus to connect either analog or digital modules. There are 10 anode blocks that i need to measure and the desired sampling frequency is 100Hz on each block. 2 for Labview 2018 and Labview 2018 FPGA Compile Farm Server. R Series Multifunction RIO devices - Install NI R Series MultifunctionRIO 15. Hello all, i am responsible to decide how LV (+ necessary hardwares from NI) deals with an existing robot using its ethercat connection, but everyday i have to spend too much time, eg restarting MAX or the whole host computer because everytime it faces problems connecting to the hardware. CompactRIOリアルタイムコントローラにあるシリアルポートの最大ボーレートは何ですか? どのようにシリアルポートを構成するのですか? ホームページに戻るNI cRIO 9024 with the Quanser Rotary Inverted Pendulum by Tabraiz on 03-07-22 03:22 AM Latest posted 03-07-22 by Tabraiz 1 0 Designing and Development of Automated Thermal Test Laboratory Solution for Wireless Customer-Premises Equipment (CPE) Thermal TEST CPE LabWindows CVI LabVIEW NI Multifunction DAQ. My NI Max software recognizes my Ethernet attached cRIO (NI cRIO-9024) but labview 2020 won’t. "The following steps show how to install NI-VISA on your cRIO: 1. This document describes how to maintain the CMS-9024 NI Condition Monitoring System. yuya-isさん LabVIEWのメニューバーの ヘルプ > サンプルを検索 で表示されるサンプルファインダにある ハードウェア入力と出力 > CompactRIO 以下に様々なサンプルがあるので参考になると思います。. crio 9024 NI 9403. RJ-45 Ethernet Port 6. . 修理、RMA、キャリブレーション予定. The CompactRIO real-time controller (NI cRIO-9024) has an 800 MHz industrial processor that balances low power consumption and powerful real-time control algorithms, signal analysis, and data logging. Software Support for CompactRIO, CompactDAQ, Single-Board RIO, R Series, and EtherCAT. lvmodel was not supported for VxWorks ope. lvmodel in order to use it as I did with simulink models. 2 and the subnet mask is 255. 466792. ご案内情報を提供いたします。. The cRIO-9024 does not include integrated C Series I/O module slots, so to use C Series I/O modules, you can combine. k-waris. To fix this problem, try the following steps: Delete the device from MAX by right-clicking on the remote target in MAX and clicking Delete. Board Model Name Board Part Number Range . You can program the chassis using Scan Mode for fast expansion of your real-time system or using the onboard FPGA for inline. As of LabVIEW Real-Time 8. xx. Open a service request. Thus, NI-9881 is not supported when used in cRIO-910x or cRIO-907x reconfigurable chassis but only in cRIO-911x chassis or in cRIO-903x, 904x, 905x, 906x and 908x. LEDs 2. x. This rugged, fanless controller features a variety of connectivity ports, including two Ethernet, one USB, and one serial. 22. cRIO-9024 Front Panel. The module is compatible with NIcRIO-9024 controllers paired with the NI cRIO-9113 chassis. Manufacturer: National Instruments. 1. Hello, I have trying to acquire analog data with a NI-9207 module (analog inputs) mounted on a cRIO-9024. If you filled an entire 8 slot chassis with 9215 modules you would use about 12 MB/s. This pro. Supported Modular Chassis: cRIO-9111, cRIO-9112, cRIO-9113, cRIO-9114, cRIO-9116, and cRIO-9118. Options. Hi, all . The FTP connection won't work anymore. 800 MHz CPU, 512 MB DRAM, 4 GB Storage CompactRIO Controller (Legacy)—The cRIO‑9024 is an embedded real-time controller ideal for advanced control and monitoring applications. With a cRIO-903x chassis and a NI-9860 XNET module you shouldn't have to compile an FPGA at all. 919 809 5227. 800 MHz CPU, 512 MB DRAM, 4 GB Storage CompactRIO Controller (Legacy) —The cRIO‑9024 is an embedded real-time controller ideal for advanced control and monitoring applications. cRIO SSD Firmware and Additional Drivers. The main parts of the cRIO system are: a real -time computer, a Field -Programmable Gate Array (FPGA) module, and a slots' bus to connect either analog or digital modules. Controller Slot 4. You can use this document to find it, the model of the chassis will be next to the serial number. NI cRIO 9024 with the Quanser Rotary Inverted Pendulum by Tabraiz on 03-07-2022 05:22 AM. View All Hardware. rj-45 . Side mounting kits are capable of panel/wall mount and DIN-rail mount. CompactRIO controllers deliver the latest advancements in processing and heterogeneous computing elements. niの集録および信号調整デバイスをサポートします。 ni-visa. 0089X certified. cRIO-9024 Front Panel 1 3 6 7 4 2 8 9 5 1. To. 800 MHz CPU, 512 MB DRAM, 4 GB Storage CompactRIO Controller (Legacy)—The cRIO‑9024 is an embedded real-time controller ideal for advanced control and monitoring applications. NI-488. National Instruments NI cRIO-9024 User Manual And Specifications (21 pages) Intelligent Real-Time Embedded Controller for CompactRIO. The NI cRIO-9024 is featured with a high-speed USB port. 03-31-2014 02:55 AM. NI cRIO-9024 controller pdf manual download. NI CompactRIO system (NI cRIO-9024 Controller and cRIO-9113 Chassis pictured) 4. . The cRIO‑9024 does not include. Please. CompactRIO NI cRIO-9012/9014 CompactRIO 用インテリジェントリアルタイム組込コントローラ 図 1. Could this be the problem? This cRIO/module combo was recommended to me by a NI rep with one of my requirements being sampling at 1Mhz,. Options. Product misuse can result in a hazard. Description. The data is transferred across a PCI bus which can transfer 133MB/s. LabVIEW will automatically choose the correct Xilinx Compilation Tools needed based on hardware. 联系 我们. 2. Member 08-14-2012 12:00 PM. The slave. Pop up window appears to either discover 'Existing target or device' or add new target. The cRIO-9024 has a primary power input, V1, and a secondary power input, V2. However, converted *. led 指示灯 2. Each channel has its own digital‑to‑analog converter. 6以降では、VxWorksオペレーティングシステムを使用するCompactRIOリアルタイムコントローラは、SNTPサーバと同期するように構成できます。. NI cRIO-9002/9004 Intelligent Real-Time Embedded Controller for CompactRIO Figure 1. Can you tell me your version of LabVIEW RT, and NI-RIO drivers please? I verified the problem with LabVIEW 2010 and a cRIO 9022 and it works. 다른 곳에서는 업데이트가 되는데 제가 태블릿 피씨에서 USB to Ethernet 포트로 장비를 찾아 업데이트를 진행할려고 하면 문제가 발생합니다. The Controller can directly link to the host computer if a network is not available. The configuration and acquisition VIs incorporate optimizations and best practices for the RIO platform, and you can easily. Re: issue with connecting with CompactRio 9024. Also if you are using a USB. NI cRIO-9072/9073/9074 Reconfigurable Embedded Chassis with Integrated Intelligent Real-Time Controller for CompactRIO Figure 1. Make sure you are using the correct USB Port. Call. If you are in home network which has DHCP server ,reset your IP using Hardware switch and restart your system. ni-daqmx. If you are using the cRIO-9024 in Gas Group IIC hazardous locations, you must use the device in an NI chassis that has been evaluated as Ex nC IIC T4, Ex IIC T4, Ex nA IIC T4, or Ex nL IIC T4 equipment. To format the disk and reinstall software To reset my cRIOfrom NI Measurement and Automation Explorer (NI MAX) without having to install any software (LabVIEW, LabVIEW Real-Time, cRIO driver) The method. Radar and Electronic Warfare. 4 pos. usb 端口 5. 5. NI MAX and NI System Configuration 19. com | Maintaining NI CMS-9024 Hardware for an NI InsightCM System. In this case, two cRIO model NI cRIO -9024 were used. install software on ni-9024. The CompactRIO real-time controller (NI cRIO-9024) has an 800 MHz industrial processor that balances low power consumption and powerful real-time control algorithms, signal. Re: custom device / I am trying to use a vehicle controller model developed in LabVIEW with compactRIO (cRIO-9024) Hongjuncho. I look for help but didn't solve my problem. 400 MHz CPU, 128 MB DRAM, 2 GB Storage, Extended Temperature CompactRIO Controller (Legacy) —The cRIO‑9014 is an embedded real-time controller ideal for advanced control and monitoring applications. Product misuse can result in a hazard. m3rv89. Can u plz help?in fpga mode i just face errors the whole time, like " a connection. xx/u:/ in the address bar, where xx. ni gpibコントローラおよびgpibポートを備えたni組込コントローラをサポートします。After a restart of the whole system the cRIO again only starts in the safe mode. The hardware includes the NI Real-Time PXI controller, CompactRIO, Single-Board RIO, and Expansion Chassis. I'm having trouble setting up a cRIO-9024 and a CRIO-9014 (not at the same time) with the latest versions of Labview and Windows 10. Check the xml in your . Lizenzverträge von National Instruments und Rechtshinweise von Drittanbietern. NI Part Number: 375896A-01 . cRIOコントローラを正常に検出するには、 CompactRIOシステムのセットアップ ガイドの手順をおこないます。. This rugged, fanless controller features a variety of connectivity ports, including two Ethernet, one USB, and one serial. USB Retention Standoff 6. You also can use the Mini DisplayPort to add a local human machine. dip 开关 8. This software-designed controller features an FPGA, a real-time processor running the NI Linux Real-Time OS, and embedded user interface capability. 783832-02. Side mounting kits are capable of panel/wall mount and DIN-rail mount. Lizenzverträge (EULAs) von National Instruments. To help you achieve the specified analog module accuracies for cRIO systems containing a cRIO-9022 or cRIO-9024 and/or cRIO-911x we recommend you adhere to the following guidelines (note. 800 MHz CPU, 512 MB DRAM, 4 GB Storage CompactRIO Controller (Legacy)—The cRIO‑9024 is an embedded real-time controller ideal for advanced control and monitoring applications. I am working with a cRIO-9024 chassis with a 9870 card also attached for additional serial ports, bringing my total available up to 5. Provides support for Ethernet, GPIB, serial, USB, and other types of instruments. Applications Engineer National Instruments 0 Kudos Message 2 of 20 (4,764 Views) Reply. 4. usb 固定螺丝 6. Solution. It seems like outputs don't respond to inputs / cRIO-9024, custom device, NI VeriStand, ControlDesk of dSPACE Hongjuncho. カスタマイズ可能で正確でありながら費用効果の高い方法で. This rugged, fanless controller features a variety of connectivity ports, including two Ethernet, one USB, and one serial. この命名規則の変更により、各LabVIEW Real-Timeバージョンで、どのRTOSがリリースされたのかを簡単に識別できるようになりました. I apply an input, and I can see the values update. In NI-MAX click the Login button on the toolbar after you have selected your target, and enter the username and password. Added support for cRIO-9023, NI 9792, and EVS-146x Series. 07-06-2011 11:03 PM. Your system requires LabVIEW FPGA & Real TIme to communicate with cRIO RT system. It features an industrial 800 MHz real-time Freescale processor for deterministic, reliable real-time applications and contains 512 MB of DDR2 RAM and 4 GB of nonvolatile storage for holding programs. Reconfigurable Embedded Chassis 3. 重置按钮 7. Electric Vehicle Test. LabVIEW开发系统. This rugged, fanless controller features a variety of connectivity ports, including two Ethernet, one USB, and one serial. NI myRIO USB Monitor start page does not appear after connecting myRIO. cRIO-9012 cRIO-9014 cRIO-9022 cRIO-9023 cRIO-9024 cRIO-9025: cRIO-9111 cRIO-9112 cRIO-9113 cRIO-9114 cRIO-9116 cRIO. The controller I am using is CompactRIO NI cRIO-9024. 0. LabVIEW FPGA模块 (仅当您想直接对FPGA进行编程时才需要). Also i have NI 9201 for voltage measurement across temperature sensor. 6. 2. Figure 2. Hello Ali_H, I am using labview 2013 with RIO0-7851R, and I met the same problem, that is the code is eating the DSP48s but keeping the slice LUT and registers at low consumption. It includes a Kintex-7 70T FPGA with LabVIEW FPGA Module support for advanced control and coprocessing. Mark as New; Bookmark; Subscribe; Mute; Subscribe to RSS Feed;. NI CompactRIO and Drivers 2022 Q3 supports the following operating systems: Windows 11. cRIO-9024 and 9014 Windows 10 Compatibility. Figure 1. 2. Open a service request. cRIO-9024 cRIO-9025 cRIO-9072 cRIO-9073 cRIO-9074 cRIO-9075 cRIO-9076. 4. NI PS-15 Power Supply User Manual. led 指示灯 2. ni의 수집 및 신호 컨디셔닝 디바이스에 대한 지원을 제공합니다. I've installed Labview 2018 SP1, Labview 2018 FPGA Module(64 bit), Xilinx Compilation Tools - Vivado 2017. Alternatively, you may trigger the acquisition via a shared variable over Ethernet; in this case you need a computer to control the cRIO remotely. Mswn. The CompactRIO real-time controller (NI cRIO-9024) has an 800 MHz industrial processor that balances low power consumption and powerful real-time control algorithms, signal analysis, and data logging. Refresh MAX to allow it to find the remote target, and check if the device still shows "Inconsistent IP Settings. Either NI-VISA is not installed on this system, or NI-VISA does not support creating new resources on this type of system. NI CompactRIO 20. I have issues 1. You can program the chassis using Scan Mode for fast expansion of your real-time system or using the onboard FPGA for inline processing. NI Part Number: 375896A-01 . Solution. ni crio-9023 compactrio 智能实时嵌入式控制器 本文档主要介绍ni crio-9023 的安装、使用方法以及产品规范。 图 1. The symptoms are that several loops in the RT application seems to be killed by some OS stuff. I was able to connect to it on a desktop computer (same cable) which is running LabVIEW 2009, MAX 4. NI-PS-14/15/16/17 Panel Mount Brackets Installation Guide. Picture is attached. from two different cRIO-9024 chassis? What is the easiest way to do that? 0 Kudos Message 1 of 2 (5,879 Views) Reply. The solution is the main thing. The cRIO-9047 is a rugged, high-performance, customizable embedded controller that offers Intel Atom quad-core processing, NI-DAQmx support, and an SD card slot for data-logging, embedded monitoring, and control. This simulink model is already test and it was ok. LabVIEW Real-Time 8. 902x Series cRIO 7870718-01, 781174-01 . 0: procedure. サンプルプログラムの PWM Generation. DMA FIFO Channels; FlexRIO 797x: 32: cRIO-904x cRIO-903x cRIO-906x NI 9147 NI 9149 PCIe-1473 FlexRIO 796x myRIO PXIe-782xR PXIe-784xR PXIe-785xR sbRIO-9607 sbRIO-9627 sbRIO-9637 sbRIO-9651 USRP-294xR: 16:. This rugged, fanless controller features a variety of connectivity ports, including two Ethernet, one USB, and one serial. zip 37 KB. The controller automatically attempts to connect to the network using DHCP. I am working on cRIO-9014 and I want to program the FPGA target of the controller. Try finding it by right-clicking on Network Devices and select Find Network NI-DAQmx Devices. " Check and see if the System Configuration versions for the Host and the Real Time target. Captive Screws 3. NI-XNET 18. This rugged, fanless controller features a variety of connectivity ports, including two Ethernet, one USB, and one serial. Options. 3. Get a decent sine generator and 5 simultanious analog inputs. xx. I have noticed that when I first deploy after a complete power cycle, the embedded logger works great - responding immediately to a change in the Log Trigger value. Reset Button 2. A valid service agreement may be required. Provides support for NI GPIB controllers and NI embedded controllers with GPIB ports. The cRIO‑9024 does not include. Reboot the device. 0. View all articles. Member. LEDs 2. 800 MHz CPU, 512 MB DRAM, 4 GB Storage CompactRIO Controller (Legacy)—The cRIO‑9024 is an embedded real-time controller ideal for advanced control and monitoring applications. The convenient Q1-cRIO set of I/O and connectors minimizes setup time and errors so students can concentrate on learning the fundamentals of controls. This model has a maximum transfer speed of 480 MB/s and a maximum power usage of 500 mA. How do i determine what chassis are compatible with the cRIO-9024? Is there document that lists them out? THe cRIO-9024. I am setting up a CompactRio 9024 for the first time. ThankyouNI-XNET 19. Applications Engineering National Instruments 0 Kudos Message 2 of 4 (2,640 Views) Reply. The software includes LabVIEW, the LabVIEW FPGA Module, the LabVIEW Real-Time Module, NI-RIO, and NI-Industrial Communications for CANopen. Added support for new C Series modules, including the NI 951x Motion modules. cRIO-9002. CanOPEN over EtherCAT is industry standard. Options. View and Download National Instruments NI cRIO-9024 user manual and specifications online. . 3. This software-designed controller features an FPGA, a real-time processor running the NI Linux Real-Time OS, and embedded user interface capability. C Series I/O Cable & Accessory Compatibility Guide. LabVIEW FPGA模块 (仅当您想直接对FPGA进行编程时才需要). User Accessible/ Battery . National Instruments cRIO-9002 CompactRIO Controller with 64 MB nonvolatile memory and 32 MB DRAM. Power Connector 3. Mark as New; Bookmark; Subscribe; Mute; Subscribe to RSS Feed; Permalink;. To restore my CompactRIO (cRIO), sbRIO, PXI Real-Time controller, stand-alone USRP controller, or other real-time targets to factory default. NI cRIO-9022 Intelligent Real-Time Embedded Controller for CompactRIO This document describes how to set up and use the NI cRIO-9022 and contains specifications for the controller. When a valid IP address has been assigned to the target, refresh NI MAX, and you should be able to install/deploy software as the "Devices and Interfaces" and "Software" tabs should be visible. CompactRIO를 프로그래밍하려면 컴퓨터에 아래 순서대로 소프트웨어가 설치되어 있어야 합니다. Options. I have tried using Labview 18, and have just tried version 19, but without success. Re: Problems connecting to cRIO-9024 in MAX. Likely the target has 2012 LabVIEW Real-Time installed on it, and you are. The hardware I'm using is NI cRIO-9076 but I have the same problem with a cRIO 9024 + chassis cRIO 9114. I am new to working with LabVIEW, and I am currently attempting to install software onto a Compact RIO NI-9024 under LabVIEW 8. The problem is whenever I start my cRIO-9072, I have to undeploy all my digital modules and redeploy it again in order for it to detect the digital output modules. Hi, I have a cRIO-9024 with NI-VISA 14. We are trying to establish an EtherCAT communication between a cRIO 9024 as EtherCAT master with a 3rd party frequency comverter (bmaxx 4432) as EtherCAT slave. Show More Description. NI cRIO-9072/9073/9074 Reconfigurable Embedded Chassis with Integrated Intelligent Real-Time Controller for CompactRIO Figure 1. NI is now part of Emerson. x. This article explains how to restore a LabVIEW Real-Time device to the factory default configuration. cRIO sh. NI-XNET 17. Associated Part Numbers: 193965-01L, 193965E-01L, 193965G-01L, 193965H-01L, 193965J-01L, 781174-01. LabVIEW FPGA Module (required only if you want to program the FPGA directly) NI CompactRIO drivers. CompactRIO Controller. cRIO-9024 Operating Instructions and Specifications Where to Go for Support National Instruments corporate headquarters is located at 11500 North Mopac Expressway, Austin, Texas, 78759-3504. 这款坚固的无风扇控制器提供了多种连接端口,包括两个以太网、一个USB和一个串行端口。. The hardware includes PC, the NI PXI controller, and CompactRIO. See System Configuration Release Notes and select the version you are interested in. Mark as New; Bookmark; Subscribe; Mute; Subscribe to RSS Feed; Permalink; Print;. As you may read in my initial posts I could not discover the C modules with the ScanEngine, but they showd up in the FPGA project. N/A. 19. The table below provides a summary of the number of DMA Channels available on NI FPGA hardware. ni gpibコントローラおよびgpibポートを備えたni組込コントローラをサポートします。800 MHz CPU, 512 MB DRAM, 4 GB Storage CompactRIO Controller (Legacy)—The cRIO‑9024 is an embedded real-time controller ideal for advanced control and monitoring applications. 2. ご希望の項目を選択してください。. Engineers at the University of Zürich have used the WR design to build a C-series module for the cRIO. Can any body tell me that I can interface Matlab with this specific RIO system and access all the ports from Matlab/Simulink? NI claims the interface should be similar to their CompactDAQ devices, and not similar to the (older) cRIO devices. View All (2) 0 Kudos Message 1 of 3 (4,268 Views) Reply. Find quaint shops, local markets, unique boutiques,. This page documents all the applicable standards and certifications for the cRIO-9024 and provides downloadable certifications. 0. The cRIO‑9025 does not include. I am working with the cRIO-9024 and four different modules. Chassis Connector 4. Disconnect the device from power and from the computer. 0. 1. png 70 KB. 04-30-2020 03:21 PM. This rugged, fanless controller features a variety of connectivity ports, including two Ethernet, one USB, and one serial. The cRIO-9038 is a rugged, fanless, embedded controller that you can use for advanced control and monitoring applications. The budget is not a problem. 5. Slide the controller onto the controller slot on the chassis. Call.